This paper presents an algorithm for current transformer (CT) saturation classifications based on correlation technique for bus bar protection. The algorithm calculates the correlation coefficient between the saturated secondary current of the faulted circuit and the summation of the other secondary currents for the un-faulted circuits. The technique classifies the degree of the CT saturation to weak, moderate and severe saturations. The results indicate that the technique is very accurate and useful in selecting the more suitable operating characteristics for differential relays to avoid the false operation.
机译:本文介绍了一种基于汇流条保护相关技术的电流互感器(CT)饱和度分类算法。 该算法计算故障电路的饱和二次电流与未断层电路的其他二次电流的求和之间的相关系数。 该技术将CT饱和度的程度分类为弱,中等和严重的饱和度。 结果表明,该技术非常准确,并且有用在选择用于差动继电器的更合适的操作特性以避免虚假操作。