Improved visualization of spiculated masses with digital breast tomosynthesis: how does size measurement correlate with pathology?

机译:通过数字化的乳房断层合成术,可以更好地观察到弥漫性的弥漫性肿块:大小测量与病理学有何关系?

获取原文

摘要

Objectives: To assess the accuracy of size measurements of spiculated masses for both 2D mammography (MX) and Digital Breast Tomosynthesis (DBT) in comparison to histopathologic outcomes in breast cancer patients.Methods: A retrospective study was conducted from January 2015 till December 2016 with inclusion of biopsy proven breast cancer patients who presented themselves with masses with spicules. Two readers performed size measurements of both the masses only as well as of the masses with spicules. Results were compared to histopathological results. Results: A total of 180 spiculated masses were included in this study. Analysis showed that for the mass only measurements both readers showed a significant underestimation on both 2D Mx as well as DBT versus histopathology. While the mass with spicules measurements showed more variable results, partly depending on tumor size and clinical working experience. We found no influence of viewing direction or breast density.Conclusions: Even with DBT it is very difficult to determine the correct size of spiculated mases. Measurements of only the central mass are not correlating well with histopathology. Especially for larger masses (> 25mm), radiologists tend to underestimate the size of spiculated masses. For smaller masses measurement of the mass center only as well as inclusion of the spicules correlated well with pathology sizes.
机译:目的:评估2D乳腺摄影(MX)和数字乳腺断层合成术(DBT)相对于乳腺癌患者组织病理学结果的大小的精确度。方法:回顾性研究于2015年1月至2016年12月进行。包括活检证实的乳腺癌患者,这些患者表现为带有针头的肿块。两个读取器仅对两个肿块以及带有尖头的肿块进行了尺寸测量。将结果与组织病理学结果进行比较。结果:本研究共包括180个香料状的肿块。分析表明,对于仅质量的测量,两个阅读器均显示出2D Mx以及DBT与组织病理学之间的显着低估。针刺的质量测量结果显示出更多的可变性,部分取决于肿瘤的大小和临床工作经验。我们没有发现观察方向或乳房密度的影响。结论:即使使用DBT,也很难确定正确的大小。仅中心质量的测量值与组织病理学关系不大。尤其是对于较大的肿块(> 25mm),放射线医师往往低估了切成小块的肿块的大小。对于较小的肿块,仅对质心进行测量,以及包含的针刺与病理学大小均具有良好的相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号