The design of De Montfort MK2 electrical impedance mammography system

机译:De Montfort MK2电阻抗乳腺X线摄影系统的设计

获取原文

摘要

We have developed a new impedance tomography imaging system for measurement of breast tissue. The system is based around a high-speed digital controller for the collection of complex electrical impedance measurements over the bandwidth 1 kHz-5 MHz. The design provides for the control of a number of factors, such as number of frequencies and frequency range etc. The data acquisition system provides an overall accuracy of better than 1%. It is now being used for the collection of impedance measurements from human breast tissue in-vitro.
机译:我们开发了一种用于测量乳房组织的新阻抗断层扫描成像系统。该系统基于高速数字控制器,用于在带宽1kHz-5MHz上集合复杂的电阻测量。该设计提供了对多种因素的控制,例如频率和频率范围等。数据采集系统提供优于1%的总体精度。它现在用于从体外人的乳腺组织收集阻抗测量。