首页> 外文会议>日本建築学会大会;日本建築学会 >Full-Scale Shake Table Tests on Frame-Spine System with Force Limiting Connections Part 2: Test Results
【24h】

Full-Scale Shake Table Tests on Frame-Spine System with Force Limiting Connections Part 2: Test Results

机译:Full-Scale Shake Table Tests on Frame-Spine System with Force Limiting Connections Part 2: Test Results

获取原文

摘要

Shake-table tests were conducted to validate thebenefit of frame-spine-FLC systems over frame-spine systems.Major findings are listed below:1) As intended, the use of force-limiting connections (FLCs) inplace of rigid connections between the frame and spine led toreduced story acceleration in the structural system.2) The deformation between the frame and spine to obtain thebenefits of FLCs was on the order of 20 to 40 mm.Work is continuing to process the data obtained from the testsand to develop a rational design procedure for frame-spine-FLCsystems.
机译:进行了振动台试验,以验证试验结果