Due to the dramatic growth of the power demand in Pudong area, Shanghai, SMEPC has applied 35kV single-core cable circuit with high strength, large section of 630mm2 and length of more than 8km in its distribution system. On one hand, the single-core cable circuit with large section can improve the transmission capacity of the single cable circuit, so that less joints will be used, the pavement and its accessories installation will be convenient, the operation and maintenance expenses will drop. On the other hand, it causes the induced voltage and circulating current on the metal sheath, which will affect the secure, reliable, stable and economical operation of the cable circuit. Since the field condition of 35kV cable pavement is totally different with that of the theoretic calculation, the calculation result has big deviation with the test result. Based on the theoretic calculation and analysis, research and analysis on the field test result of the induced voltage and circulating current on the metal sheath of 35kV 630mm2 single-core XLPE cable circuit, this paper assesses the soundness of the cable circuit with large section and long distance objectively and scientifically, submits the optimized solution to effectively restrain the induced voltage and circulating current.
机译:鉴于上海浦东地区电力需求的急剧增长,中电集团在配电系统中采用了强度高,截面积大630mm 2 ,长度超过8km的35kV单芯电缆电路。一方面,大截面的单芯电缆电路可以提高单电缆电路的传输能力,从而减少了接头的使用,使人行道及其配件的安装更加方便,降低了运维费用。另一方面,它会在金属护套上引起感应电压和循环电流,这将影响电缆电路的安全,可靠,稳定和经济运行。由于35kV电缆路面的现场条件与理论计算完全不同,因此计算结果与试验结果有较大偏差。在理论计算和分析的基础上,对35kV 630mm 2 单芯交联聚乙烯电缆金属护套上的感应电压和环流的现场测试结果进行了研究和分析,以评估其合理性。客观科学地对大截面长距离电缆电路的方案进行了优化,提出了有效抑制感生电压和环流的优化方案。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号