Inoculating excess sludge was adopted by most wastewater treatment plants (WWTP). But inoculating excess sludge has these problems usually: high cost for buying, transportation and dosing number seeding sludge, and activated sludge having lag phase. Inoculating primary sludge is supposed a promising method. The total bacterial count of the influent and effluent was detected by DAPI (4′, 6-diamidino-2-phenylindole) staining in primary sedimentation. And the total bacterial count of the effluent was 9.7% of that in the influent on an average. Most of bacterial was settled with primary sludge. The comparative study has been done about the start-up of an activated sludge system by inoculating primary sludge and no primary sludge. The result showed that: at 20°C, in the system which was inoculated primary sludge, the mixed-liquor suspended solids (MLSS) was 2815mg/L, the ammonia nitrogen and Chemical Oxygen Demand(COD) in effluent were 0.65 mg/L and 47.6 mg/L respectively on the 9th day, so the start-up was succeed. Primary sludge is a kind of cheap seeding sludge, which can be obtained easily in WWTP, and the activated sludge system can be quick started up easily by inoculating primary sludge.
机译:大多数废水处理厂(WWTP)都采用接种过量污泥的方法。但是接种过量的污泥通常存在以下问题:购买,运输和加药数量接种污泥的高成本,以及具有滞后阶段的活性污泥。接种初级污泥被认为是一种有前途的方法。在初次沉淀中,通过DAPI(4',6-diamidino-2-phenylindole)染色检测进水和出水的细菌总数。平均而言,废水的总细菌数为进水细菌总数的9.7%。大部分细菌沉淀在初级污泥中。通过接种初级污泥和不接种初级污泥,已经进行了有关活性污泥系统启动的比较研究。结果表明:在20℃下,接种初级污泥的系统中,混合液悬浮物(MLSS)为2815mg / L,废水中氨氮和化学需氧量(COD)为0.65 mg / L。第9天分别为47.6 mg / L和47.6 mg / L,因此启动成功。初级污泥是一种廉价的播种污泥,可以在污水处理厂容易地获得,并且通过接种初级污泥可以很容易地快速启动活性污泥系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号