摘要

Towards the reactive compensation feature of distribution network and integral substation, this paper proposed an integration structure of distribution transformer and STATCOM (DT-STATCOM). It use the surplus capacity of transformer to compensate the reactive power; by setting the connect voltage flexible, it extended the switching devices selection; the integration structure reduce the volume and cost of compensation device. Based on the structure of DT-STATCOM, this paper proposed two novel reactive current detection method across the transformer's ports. Then the paper designed the decision control system using multi-lateral information. Simulation result showed that, the DT-STATCOM system had significant effect on dynamic reactive power compensation, transformer voltage support and imbalance inhibition.
机译:针对配电网和变电站无功补偿的特点,提出了配电变压器与STATCOM(DT-STATCOM)的集成结构。它利用变压器的剩余容量来补偿无功功率。通过灵活设置连接电压,扩展了开关设备的选择范围。一体化结构减少了补偿装置的体积和成本。基于DT-STATCOM的结构,本文提出了两种新颖的跨变压器端口无功电流检测方法。然后,本文利用多边信息设计了决策控制系统。仿真结果表明,DT-STATCOM系统对动态无功补偿,变压器电压支持和不平衡抑制有显着影响。