首页> 外文会议>World conference on timber engineering;WCTE 2012 >Highly insulated wooden structures in Nordic climate
【24h】

Highly insulated wooden structures in Nordic climate

机译:北欧气候中高度绝缘的木结构

获取原文

摘要

Since many years there are discussions in Nordic countries about the moisture behaviour of highly insulated wooden structures and fully insulated roof structures without ventilation gap. Moisture accumulation is feared, leading to possible mould problems in the structures. Actual simulation programmes like WUFI® [1] are not fully evaluated for the Nordic climate conditions and might not be accurate, hence they cannot reliably proof the operational reliability of the structures. Therefore three test houses were built at Aalto University to investigate the moisture and temperature behaviour of different wooden structures in the Southern Finnish climate. Measurements started in December 2011 for three different types of timber structures from lightweight to massive timber combined with various insulation materials and vapour resistances of the structures. The measured data was then compared to numerical WUFI® simulations.
机译:多年来,北欧国家一直在讨论高度绝缘的木结构和没有通风间隙的完全绝缘的屋顶结构的防潮性能。担心水分积聚,导致结构中可能出现霉菌问题。诸如WUFI®[1]的实际模拟程序并未针对北欧气候条件进行全面评估,因此可能并不准确,因此它们无法可靠地证明结构的运行可靠性。因此,阿尔托大学建立了三个测试室,以研究芬兰南部气候下不同木结构的湿度和温度行为。从2011年12月开始对三种不同类型的木结构进行测量,这些木结构从轻量级木材到大块木材,并结合了各种绝缘材料和结构的耐蒸汽性。然后将测得的数据与数值模拟进行比较。