Wall nucleation experiments have been performed in a vertical annulus test section for investigation of the bubble departure diameter and bubble departure frequency. The experimental data in forced convective subcooled boiling flow is presented as a parametric study of the effect of wall heat flux, local bulk liquid sub-cooling, liquid flow rate, and system pressure. The data is shown to extend the database currently available in literature to a wider range of system conditions. Along with the current database in forced convective flow, the available models for bubble departure size and frequency are reviewed and compared with the new data. The prediction of the bubble departure frequency is shown to require accurate modeling of the bubble departure diameter which has poor agreement with the experimental database.
机译:壁成核实验已经在垂直环形试验部分进行,用于研究气泡偏离直径和气泡脱离频率。强制对流过冷沸腾流程中的实验数据被呈现为壁热通量,局部散装液体子冷却,液体流速和系统压力效果的参数研究。数据显示为将文献中当前可用的数据库扩展到更广泛的系统条件。随着强制对流流程中的当前数据库,与新数据进行审查并与频率进行频率的可用模型。泡沫脱离频率的预测显示需要精确建模的气泡偏离直径,这与实验数据库差不良。