Combined Close Interval Potential Surveys (CIPS) and Direct Current Voltage Gradient (DCVG) surveys when combined with GPS time and location stamping ensure improved integrity and accuracy of data collected. Close interval potential surveys are the backbone of pipeline integrity. They assess the effectiveness of the cathodic protection (CP) system which provides protection against corrosion. Direct current voltage gradient surveys indicate defects or damage in the coating on the pipeline but do not indicate the level of cathodic protection. CIPS and DCVG surveys have traditionally been undertaken independently which has made it difficult to correlate coating defects with the level of cathodic protection as indicated by pipe-to-soil potentials. This paper will explore the effectiveness of combined CIPS and DCVG surveys for improved data correlation.
机译:结合使用GPS时标和位置标记,结合了紧密间隔电位调查(CIPS)和直流电压梯度(DCVG)调查,可确保提高收集数据的完整性和准确性。近距离潜在调查是管道完整性的基础。他们评估了提供腐蚀防护的阴极保护(CP)系统的有效性。直流电压梯度调查表明管道上的涂层有缺陷或损坏,但没有指出阴极保护的水平。传统上,CIPS和DCVG调查是独立进行的,这使得很难将涂层缺陷与管道对土壤电势所指示的阴极保护水平相关联。本文将探讨CIPS和DCVG组合调查对于改善数据相关性的有效性。