The measurement of shielding effectiveness of coaxial cables isoften limited by the dynamic range of the measurement system. This paperdiscusses the methods used to establish a dynamic range of 150 dB at 1GHz, and 120 dB at 18 GHz, using a small reverberation chamber tomeasure the shielding effectiveness of coaxial cables. The chamber usedhad dimensions of 1.8×1.2×0.8 m