Improved Phase-coordinate Fixed-point Iterative Method Based on Equivalent Admittance Approximation for Power Flow Calculation in Three-phase Distribution Systems

机译:基于三相分布系统电流计算的等效导差近似的改进的相位坐标定点迭代方法

获取原文

摘要

This paper proposes an improved and unified fixed-point iterative method to solve the power flow problem in three-phase distribution systems by phase-coordinates. The proposed method which has definitude physical meaning in essence is to searching for the equivalent admittance approximations of the loads. And an improved decoupled method in topology for modeling the distribution equipment is given, which makes the models of distribution equipment easy to integrate into the proposed method. The solution characteristics analysis of the proposed method is given as well. The validity and effectiveness of the proposed method can be demonstrated by the numerical test systems.
机译:本文提出了一种改进和统一的定点迭代方法,通过相位坐标解决三相分布系统中的功率流问题。所提出的方法实质上具有明确的物理含义,是寻找负载的等同导纳近似值。给出了用于建模分配设备的拓扑中的改进的解耦方法,这使得配送设备的型号易于集成到所提出的方法中。还给出了所提出的方法的溶液特征分析。可以通过数值测试系统证明所提出的方法的有效性和有效性。