首页> 外文会议>International Conference on Greenhouse Gas Control Technologies >TEST RESULTS OF CO_2 CAPTURE BY ANTI-SUBLIMATION CAPTURE EFFICIENCY AND ENERGY CONSUMPTION FOR BOILER PLANTS
【24h】

TEST RESULTS OF CO_2 CAPTURE BY ANTI-SUBLIMATION CAPTURE EFFICIENCY AND ENERGY CONSUMPTION FOR BOILER PLANTS

机译:通过防升升捕获效率和锅炉植物能耗的CO_2捕获的测试结果

获取原文

摘要

A previous paper presented the concept of frosting and defrosting CO_2 at atmospheric pressure on a low temperature evaporator. Based on this concept a test bench has been designed, realized and tests have been carried out. The CO_2 defrosting process as designed requires a swing process on 2 low temperature evaporators. The swing process enables to recover the sublimation and the melting CO_2 energy for temperatures varying during the defrosting process between -120°C and -56°C. Energy efficiency of the global CO_2 capture process can now be calculated based on these experimental results. Step by step calculations, taking into account the water and the CO_2 concentrations in the flue gases are presented indicating the energy determining steps of the process.
机译:先前的论文在低温蒸发器上呈现了在大气压下在大气压下冻结和除霜CO_2的概念。基于这一概念,已经设计了测试台,实现,并进行了测试。设计的CO_2除霜过程需要在2个低温蒸发器上进行摆动过程。摆动过程使得能够在-120℃和-56℃之间的除霜过程中改变的温度变化的温度和熔融CO_2能量。现在可以根据这些实验结果计算全局CO_2捕获过程的能效。逐步计算,考虑到水和烟道气中的CO_2浓度表示该过程的能量确定步骤。