In order to explore the new features of the novel combined cryosurgery/hyperthermia cryoprobe from the viewpoint of thermal stress, the heat transfer and thermal stress problems during the common cryosurgery process using this cryoprobe and the Endocare cryoprobe were comparatively studied. The enthalpy form of the classical bioheat equation coupled with the stress equations was solved by using the commercial software Ansys (version 7.0). The tissues were treated as nonideal materials freezing over a temperature range, and the thermophysical and mechanical properties of which were temperature dependent. The model was verified using the finite difference method put forward by us recently. The two kinds of cryoprobes capable of heating during the rewarming process, i.e. the novel combined cryosurgery/hyperthermia cryoprobe and the Endocare cryoprobe, were then studied using the verified model.
机译:为了从热应力的观点来探讨新型组合冷冻胶或高温高温探针的新特征,使用该冷冻探针和endocare冷冻探针在​​常见的冷冻胶层过程中的传热和热应力问题进行了相对研究。通过使用商业软件ANSYS(7.0版)解决了与应力方程耦合的经典生物发热方程的焓形式。将组织视为在温度范围内冻结的非膜材料,其热性和机械性能为温度依赖性。使用最近提出的有限差分方法验证了该模型。在复活过程中能够加热的两种冷冻毛细管,即使用经过验证的模型研究新型组合的冷冻热毛细管/高温毛细血管和Endocare冷冻探针。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号