In Power Supply Capability evaluation, the method based on the interconnections among main transformers produces the exceeding margin. Taking the cause into consideration, this paper proposes a method to correct the load rate matrix of interconnection schemes that is based on the advantages of the former method. Firstly, the minimum load rate of each interconnection scheme is searched and recorded, according to which the same column are corrected. Secondly, the margins produced in the former step are distributed to each main transformer of the same interconnection scheme according to the N-1 guideline. The method completes after the traversal of load rate matrix. Finally, it is demonstrated that this method obtains a more accurate result by the calculation of practical example.
机译:在电源能力评估中,基于主变压器之间的互连的方法产生超过余量。考虑到归因于,本文提出了一种校正基于前方法的优点的互连方案的互连方案的方法。首先,搜索和记录每个互连方案的最小负载率,根据该互连方案的校正,相同的列被校正。其次,根据N-1指南将前一步中产生的边缘分布到相同互连方案的每个主变压器。该方法在负载率矩阵的遍历后完成。最后,证明该方法通过计算实际示例来获得更准确的结果。