There are several types of instruments that enable us to measure the ozone content in different conditions (in the outdoors, in moving platforms, in industrial buildings, etc.). They operate on the basis of different physical and chemical processes and have different values of parameters such as sensitivity, accuracy, response time, etc. The model of photometer for measuring the ozone concentration is described below. The instrument acts due to selective absorption of UV-radiation by ozone molecule. The distinguishing peculiarity of this device is the use of radioluminescent source (RLS) with very high long-term temporal emission stability instead of the generally used unstable mercury lamp. The RLS emission power is 3 $DOT 10$+11$/ quantum/s. Three subsystems (optical, gas-flow, and electronic) making up this photometer are described in detail. The approximate estimates of photometer threshold sensitivity and accuracy are made and the possible means for improving these parameters are outlined.
机译:有几种类型的仪器使我们能够测量不同条件下的臭氧含量(在户外,在移动平台,工业建筑物中等)。它们在不同的物理和化学过程的基础上运行,并且具有不同的参数值,例如灵敏度,精度,响应时间等。下面描述用于测量臭氧浓度的光度计模型。仪器由于臭氧分子的选择性吸收紫外线辐射而作用。该装置的区别特性是使用具有非常高的长期时间发射稳定性而不是通常使用的不稳定汞灯的放射致发光源(RLS)。 RLS排放功率为3 $ 10 $ + 11 $ /量级。详细描述了构成该光度计的三个子系统(光学,气流和电子)。概述了光度计阈值灵敏度和精度的近似估计,并且概述了用于改善这些参数的可能装置。