首页> 外文会议>ASME International Mechanical Engineering Congress and Exposition >RAMAN THERMOMETRY OF AN ELECTRO-THERMAL MICROACTUATOR
【24h】

RAMAN THERMOMETRY OF AN ELECTRO-THERMAL MICROACTUATOR

机译:电热微致动器的拉曼温度

获取原文

摘要

Experimentally measured temperature profiles along the micron-scale beam of a working thermal actuator are reported for the first time. Using a surface Raman scattering technique, temperature measurements are obtained in a noncontact fashion with submicron spatial resolution and to within an uncertainty of better than ±10 K. The experimental data are used to validate computational predictions of the actuator thermal performance with reasonable agreement between the data and predicted temperatures.
机译:首次报告沿着工作热致动器的微米级梁的实验测量的温度曲线。使用表面拉曼散射技术,以亚微米空间分辨率的非接触式方式获得温度测量,并且在更好的不确定度之中优于±10k。实验数据用于通过合理的协议验证执行器热性能的计算预测数据和预测的温度。