A temperature accelerated life test on commercial concentrator lattice-matched GaInP/GaInAs/Ge triple-junction solar cells has been carried out. The solar cells have been tested at three different temperatures: 119, 126 and 164°C and the nominal photo-current condition (820 X) has been emulated by injecting current in darkness. All the solar cells have presented catastrophic failures. The failure distributions at the three tested temperatures have been fitted to an Arrhenius-Weibull model. An Arrhenius activation energy of 1.58 eV was determined from the fit. The main reliability functions and parameters (reliability function, instantaneous failure rate, mean time to failure, warranty time) of these solar cells at the nominal working temperature (80 °C) have been obtained. The warranty time obtained for a failure population of 5 % has been 69 years. Thus, a long-term warranty could be offered for these particular solar cells working at 820 X, 8 hours per day at 80 °C.
机译:已经进行了在商业集中器格子匹配的GAINP / GAINAS / GE三界太阳能电池的温度加速寿命试验。 已经在三个不同的温度下测试了太阳能电池:119,126和164℃并且通过在黑暗中注入电流来仿真标称光电流条件(820 x)。 所有太阳能电池都呈现出灾难性的失败。 三个测试温度的故障分布已经安装在Arrhenius-Weibull模型中。 从拟合确定1.58eV的Arrhenius激活能量。 已经获得了标称工作温度(80℃)的这些太阳能电池的主要可靠性功能和参数(可靠性函数,瞬时故障率,平均故障,保修时间,保修时间)。 为期5%的失败人口获得的保修时间为69年。 因此,可以为在820 x,每天8小时的80℃下工作的这些特定的太阳能电池提供长期保修。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号