首页> 外文会议>NACE annual conference & exposition >ATMOSPHERIC CORROSION SUPPRESSION THROUGH CONTROLLED HUMIDITYPROTECTION (CHP), AN OPERATIONAL READINESS AND FORCE MULTIPLIER
【24h】

ATMOSPHERIC CORROSION SUPPRESSION THROUGH CONTROLLED HUMIDITYPROTECTION (CHP), AN OPERATIONAL READINESS AND FORCE MULTIPLIER

机译:通过控制的防潮(CHP)来抑制大气腐蚀,运行准备和强制倍增器

获取原文

摘要

Creating a Controlled Humidity Protection (CHP) environment of between 30% and 40%relative humidity stops atmospheric corrosion. The paper presents:? The relationship between relative humidity and corrosion/material degradation rates.? The extent of CHP systems deployment throughout the Department of Defense, highlighting U.S.Marine Corps, Army National Guard and Naval Aviation applications.? CHP systems in use on Aircraft, aviation and weapons Support Equipment, and other combatequipment.? DoD, U.S. Marine Corps and Naval Aviation CHP policy directives.? Independent CHP performance and economic analyses by the General Accounting Office, DoDInspector General and Army Cost and Economic Analysis Center (CEAC).? User-reported performance and economic results.
机译:创建相对湿度在30%到40%之间的受控湿度保护(CHP)环境可以停止大气腐蚀。该论文提出:?相对湿度与腐蚀/材料降解率之间的关系。 CHP系统在整个国防部的部署程度,重点是美国海军陆战队,陆军国民警卫队和海军航空兵的应用。在飞机,航空和武器支持设备以及其他战斗设备上使用的CHP系统。国防部,美国海军陆战队和海军航空CHP政策指令。由总会计办公室,DoDInspector General和陆军成本与经济分析中心(CEAC)进行的独立CHP绩效和经济分析。用户报告的性能和经济结果。