CRACKED SHAFT SLEEVE CAUSES UNUSUAL VIBRATION

机译:轴套破裂导致异常振动

获取原文
获取原文并翻译 | 示例

摘要

In the Spring of 2001, vibration on one of the Reactor Coolant Pumps in Unit 3 of the Palo Verde Nuclear Generating Station began to show indications of a shaft crack. The Station had experienced another shaft crack in Unit 1 in 1996 and monitoring and analysis proceeded on the assumption that these new indications would follow the same pattern as the previous failure. After monitoring for some time it became clear that this new problem wasn't following the same pattern. The rate of increase in vibration amplitude and phase, and eventually other 'non-crack like' symptoms indicated that the problem, although indicating a crack, was very different from the 1996 event. When the pump was eventually disassembled, an axial crack was found in the journal bearing shaft protection sleeve.
机译:在2001年春季,帕洛佛得角核电站3号机组的一台反应堆冷却泵的振动开始显示出竖井的迹象。该站于1996年在1号机组中又经历了一次竖井裂缝,并且在进行监视和分析的前提下,这些新迹象将遵循与先前故障相同的模式。监视一段时间后,很明显这个新问题并没有遵循相同的模式。振动幅度和相位的增加速率,以及最终出现的其他“非裂纹样”症状表明,该问题虽然表明存在裂纹,但与1996年的事件却大不相同。最终拆卸泵时,在轴颈轴承轴保护套中发现了轴向裂纹。