A corrosion investigation was made on 35.4 kilometers (km) (22 miles) of pipeline carrying reclaimed water after 32 years of service near Incline Village, California. The pipe was excavated in five locations and samples were cut from the pipeline for testing. Methods used in the investigation include soil resistivity analysis, laboratory soil analysis, ultrasonic thickness measurements and mechanical testing of steel samples removed from the pipeline, alkalinity and pH testing of cement mortar lining of pipe samples, and a closed circuit television (CCTV) inspection. The investigation concluded that the pipe damage was mostly due to third party construction. The steel met the material design requirements. High chlorides and sulfates led to corrosion of the exterior of the pipeline in some locations. This paper presents the findings and conclusions of the study.
机译:在加利福尼亚州Incline Village附近服务了32年的35.4公里(22英里)输送再生水的管道上进行了腐蚀调查。在五个位置开挖了管道,并从管道上切下了样品进行测试。调查中使用的方法包括土壤电阻率分析,实验室土壤分析,超声波厚度测量和对从管道中取出的钢铁样品的机械测试,管道样品的水泥砂浆衬里的碱度和pH测试,以及闭路电视(CCTV)检查。调查得出的结论是,管道损坏主要是由于第三方施工造成的。钢材符合材料设计要求。高氯化物和硫酸盐在某些位置导致管道外部腐蚀。本文介绍了研究结果和结论。