Aiming at solving an issue that the stray current increases the risk of corrosion of the buried metal with the increase of operation age in metro, some measures are proposed to protect the buried metal from stray current respectively on the stages of design, construction, operation, and protection in the metro system in this paper. Compared with the reference papers, CDEGS, professional software of grounding analysis, is applied for modeling as well as calculation, and factors are applied to decrease the leakage of stray current with regard to the electrical specification, like different supply modes, voltage classes, and so on. And when the metro is in operation, some measures, like the dust removal, waterproof, and passivation protection should be applied to reduce the risk of corrosion of buried metallic structures. Therefore, with the measures adopted, the risk of corrosion will be reduced greatly.
机译:为了解决杂散电流随着地铁运营年限的增加而增加埋地金属腐蚀风险的问题,提出了在设计,施工,运行等阶段分别采取措施保护埋地金属免受杂散电流的影响。在地铁系统中的保护和保护。与参考文件相比,采用CDEGS(接地分析专业软件)进行建模和计算,并且根据电气规格(例如,不同的供电方式,电压等级和功率),采用了减少杂散电流泄漏的因素。以此类推。并且,在地铁运营期间,应采取一些措施,例如除尘,防水和钝化保护,以减少埋入金属结构的腐蚀风险。因此,采用所采取的措施,将大大降低腐蚀的风险。