The Simplified Boiling Water Reactor (SBWR) incorporates a passive system for decay heat removal from the containment in the event of a postulated Loss-of-Coolant Accident (LOCA). Decay heat is removed by condensation of the steam discharged from the reactor pressure vessel (RPV) in three condensers which comprise the Passive Containment Cooling System (PCCS). These condensers are designed to carry the heat load while transporting a mixture of steam and noncondensible gas (primarily nitrogen) from the drywell to the suppression chamber. This paper describes the expected LOCA response of the SBWR with respect to the PCCS performance, based on analysis and test results. The results confirm that the PCCS has excess capacity for decay heat removal and that overall system performance is very robust.
机译:简化的沸水反应堆(SBWR)包含一个被动系统,用于在假定的冷却液泄漏事故(LOCA)的情况下从安全壳中去除衰变热。在三个由无源安全壳冷却系统(PCCS)组成的冷凝器中,从反应堆压力容器(RPV)排出的蒸汽冷凝,从而除去了腐烂热。这些冷凝器设计用于承受热负荷,同时将蒸汽和不可冷凝气体(主要是氮气)的混合物从干井输送到抑制室。本文基于分析和测试结果,描述了SBWR对PCCS性能的预期LOCA响应。结果证实,PCCS具有多余的衰减热量去除能力,并且整个系统性能非常强大。