摘要

In 2005, as part of a paper and presentation on reconditioning generators commonly serving the pulp and paper mill industry, the author provided information on several of the most common types of generator failure modes that occurs on these units. Common preventive maintenance tests that can be done to uncover these types of failures were also presented. The paper also included some reference information to orient and familiarize the reader with the generator's key components. This follow-up paper is written with the intent of adding to the originally presented list of generator failures that can occur on these units. Specific tests to address these additional generator failure modes are provided. Between the two papers, an excellent reference for the generator, along with most all the possible failure modes, and key electrical tests, are provided.
机译:在2005年,作为论文的一部分,介绍了常用于制浆造纸厂的修复发电机,作者提供了有关这些设备上发生的几种最常见的发电机故障模式的信息。还介绍了可以发现这些类型故障的常见预防性维护测试。本文还包括一些参考信息,以使读者熟悉并熟悉生成器的关键组件。编写此后续论文的目的是将这些单元上可能发生的发电机故障列表添加到最初显示的列表中。提供了针对这些其他发电机故障模式的特定测试。在这两篇论文之间,提供了发电机的最佳参考,以及大多数可能的故障模式和关键的电气测试。