首页> 外文会议>Radon and thoron in the human environment >Vertical Distribution of Radon Concentrations in the Atmosphere
【24h】

Vertical Distribution of Radon Concentrations in the Atmosphere

机译:大气中Rad浓度的垂直分布

获取原文
获取原文并翻译 | 示例

摘要

Vertical distributions of radon (~(222)Rn) concentrations were measured up to 5 km in the atmosphere around central Japan. About 50 L air was sampled in a Tedlar® (polyvinyl fluoride, PVF) bag by using an aircraft. The ~(222)Rn concentrations in the bags were measured with electrostatic radon monitor. The detection limit is 0.10 Bq·m~(-3) for measuring time of 6 h. The measured concentrations were corrected by considering ~(222)Rn decay rate and the atmospheric pressure at the sampling altitude. The ~(222)Rn concentration decreases rapidly with increasing altitude. The high ~(222)Rn concentrations were observed at about 500 and 1000 m under atmospheric boundary layer over the land areas. The ~(222)Rn concentrations sampled over the sea were lower due to no ~(222)Rn exhalation from the sea surface. The vertical distribution could be explained fairly well by using the analysis of air mass trajectory and one dimensional diffusion model.
机译:在日本中部大约5 km的大气中测量了((〜(222)Rn)浓度的垂直分布。使用飞机在Tedlar®(聚氟乙烯,PVF)袋中采样约50 L的空气。用静电ra监测仪测量袋中的〜(222)Rn浓度。检测时间为6 h时,检出限为0.10 Bq·m〜(-3)。考虑到〜(222)Rn衰减率和采样高度下的大气压,对测得的浓度进行校正。 〜(222)Rn浓度随海拔升高而迅速降低。在陆地区域大气边界层下约500和1000 m处观测到高〜(222)Rn浓度。由于没有从海面呼出〜(222)Rn,因此海上采样的〜(222)Rn浓度较低。利用空气质量轨迹分析和一维扩散模型可以很好地解释垂直分布。