Class 373 3-phase drive trains, although very similar to the established French TGV high-speed trains, present some new and unique challenges for safe high-speed operation over the railway infrastructure in the UK. The designated Class 373 routes were electrified and resignalled at different times since 1965 using evolving design standards. It is now mandatory to present a Safety Case for running on UK routes. The ongoing risk assessment is identifying, quantifying and resolving the train compatibility hazards on these routes. The electromagnetic compatibility (EMC) with the existing signalling equipment is the key safety issue. This papaer describes the strategies adopted for EMC risk assessments, application of safety targets, and recommendations for immunisation of the infrastructure.
机译:373类三相传动系统虽然与已建立的法国TGV高速列车非常相似,但对英国铁路基础设施的安全高速运行提出了一些新的独特挑战。自1965年以来,使用不断发展的设计标准,指定的373类路线已通电并不同意。现在必须提供在英国航线上行驶的安全案例。正在进行的风险评估是识别,量化和解决这些路线上火车兼容性的危害。与现有信号设备的电磁兼容性(EMC)是关键的安全问题。本白皮书介绍了EMC风险评估,安全目标的应用以及基础设施免疫建议的策略。