This paper will present the Footing Load Test (FLT), conceived in partnership with the UC Berkley Civil Engineering Department. The test uses a FUNDEX Pile Load Tester (PLT) (traditionally used to test deep foundations such as piers and piles) to cyclically impact full scale footings with large loads up to 800 kips. Test results were used to improve dynamic foundation design values for UC Berkeley structures. Most of the structures at the campus are founded in fractured and weathered shale and sandstone, where it is difficult to estimate the rock properties based on test boring and laboratory data, and therefore foundation design values are typically based on presumptive and/or empirical values. The FLTs provide a direct measure of foundation stiffness and bearing capacity and can be used to reduce uncertainty in design of future buildings at the Campus.
机译:本文将介绍与加州大学伯克利分校土木工程系合作构思的基础荷载测试(FLT)。该测试使用FUNDEX桩载荷测试仪(PLT)(传统上用于测试深厚基础,如墩台和桩),周期性地冲击最大载荷高达800 kips的全尺寸基础。测试结果用于改善加州大学伯克利分校结构的动力基础设计值。校园中的大多数结构都位于裂缝和风化的页岩和砂岩中,很难根据钻孔和实验室数据估算岩石特性,因此,基础设计值通常基于推定值和/或经验值。 FLT可直接测量基础刚度和承载力,并可用于减少校园未来建筑设计的不确定性。