首页> 外文会议>The Third international conference on pumps and fans(3rd ICPF) >Effect of some factors on performance of contra-rotating fan
【24h】

Effect of some factors on performance of contra-rotating fan

机译:某些因素对反向旋转风扇性能的影响

获取原文
获取原文并翻译 | 示例

摘要

This paper reports the results of an experimntal investigation on hte performance of a contra-rotating axial flow fan stage.The influence of fators such as speed ratio,axial spacing between the rotors are examined on a 0.6 hub-tip ratio fan.The experimental invrestigation reveals that the performance o fa contra-rotating fan is affeted by these factors.Results show that in a ocntra-rotating fan stage with close axial space,rotating stall on the first rotor is suppressed when the second rotor is contra-rotated at a speed 50 percent faster than the first rotor.Under such conditions,a considerable increase in stall margin improvement and stall flow margin,as well as pressure rise and lfow rate capacity were increased.the cntra-rotating fans are more efficient and economical than fans with guide vanes (rotor-stator stage.).
机译:本文报道了对流式轴流风机级热性能的实验研究结果。在0.6轮毂-顶端比风机上研究了诸如速比,转子之间的轴向间距之类的因素的影响。结果表明,在具有紧密轴向空间的正转风扇级中,当第二转子以一定速度反向旋转时,第一转子的旋转失速得到抑制。比第一个转子快50%。在这种情况下,失速裕度的改善和失速流量裕度的增加明显增加,压力上升和流量率的能力也大大提高了。叶片(转子-定子级。)。