首页> 外文学位 >Simulation analysis of TWACS system-10 and Nertec automatic meter reading networks.
【24h】

Simulation analysis of TWACS system-10 and Nertec automatic meter reading networks.

机译:TWACS system-10和Nertec自动抄表网络的仿真分析。

获取原文
获取原文并翻译 | 示例

摘要

Computer simulation is a straightforward and cost effective method of analyzing the performance of communications networks such as automatic meter reading (AMR) systems. AMR networks are a relatively new technology quickly gaining interest with major utility providers. Manitoba Hydro, as a major utility provider, has undertaken a study to evaluate the suitability of several AMR systems to operations in the City of Winnipeg. As part of this study, Manitoba Hydro desired that a simulation analysis be performed.;The TWACS System-10 and Nertec AMR systems will be modeled using the Simscript 11.5 simulation language. The intention is to determine, through simulation, if either system meet basic performance criteria set out by Manitoba Hydro. Further, it is hoped that simulation modeling will demonstrate the strengths and weaknesses of each system within the City of Winnipeg context.;The componentry and logical operation of the two systems will be described. A description of the two models constructed will be provided along with a verification of each. The performance of each system, as well as the sensitivity of each to variations in system parameters, is evaluated through simulation. The results of sensitivity analyses and performance experiments with each model are presented. These results provide insight into the performance which could be expected from either system should they be implemented in the City of Winnipeg. It is determined that, according to simulation results, the TWACS System-10 will meet the basic performance requirements of Manitoba Hydro while the Nertec System will not.
机译:计算机仿真是一种分析通讯网络(例如自动抄表(AMR)系统)性能的简单且经济高效的方法。 AMR网络是一种相对较新的技术,很快引起了主要公用事业提供商的兴趣。作为主要的公用事业提供商,曼尼托巴水电公司进行了一项研究,以评估几种AMR系统对温尼伯市运营的适用性。作为这项研究的一部分,曼尼托巴水电公司希望进行仿真分析。TWACS System-10和Nertec AMR系统将使用Simscript 11.5仿真语言进行建模。目的是通过仿真确定任何一个系统是否满足Manitoba Hydro设定的基本性能标准。此外,希望通过仿真建模来展示温尼伯市范围内每个系统的优缺点。;将描述两个系统的组成部分和逻辑操作。将提供对所构造的两个模型的描述以及每个模型的验证。通过仿真评估每个系统的性能以及每个系统对系统参数变化的敏感性。给出了每种模型的敏感性分析和性能实验的结果。这些结果提供了对在温尼伯市实施的两种系统预期性能的深入了解。根据仿真结果,可以确定TWACS System-10可以满足Manitoba Hydro的基本性能要求,而Nertec System则不能。

著录项

  • 作者

    Rankin, Laird Scott.;

  • 作者单位

    University of Manitoba (Canada).;

  • 授予单位 University of Manitoba (Canada).;
  • 学科 Engineering Industrial.;Engineering System Science.
  • 学位 M.Sc.
  • 年度 1996
  • 页码 84 p.
  • 总页数 84
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号