Due to the continuous operation of HVAC systems and stringent requirements of indoor environmental conditions, the total energy use per floor area in healthcare facilities is second only to that in food service buildings, and significantly higher than that in any other commercial building types. In order to evaluate potential opportunities for saving energy in healthcare facilities, a model of a hospital located in south Louisiana was developed in EnergyPlus simulation software. Building information required for the model development was taken from the hospital architectural and mechanical plans. Two field surveys were also conducted to identify the operating characteristics of electrical equipment and gas equipment. The annual electricity and natural gas consumption estimated by the developed model was compared with utility data for model validation. Five energy efficient measures were evaluated using the developed models, namely reducing LPD, installing high efficiency windows, the combination method of reducing LPD and window changing approaches, installing a separate chiller for OR, and another combination of LPD reduction and chiller separation. Simulation results showed 12% annual energy savings by reducing LPD from 2.5 to 0.86 W/ft2 while only 1% savings resulted from using high-efficiency windows. The combination of LPD reduction and window changing could reduce the annual energy consumption by 13%. Building energy usage has been decreased by 8% after separating the OR chiller and 18% by the combination method of reducing LPD and separating chillers.
机译:由于HVAC系统的连续运行以及室内环境条件的严格要求,医疗保健机构每层面积的总能耗仅次于餐饮服务建筑物,仅次于餐饮业建筑物。为了评估在医疗机构中节省能源的潜在机会,在EnergyPlus模拟软件中开发了位于路易斯安那州南部的一家医院模型。模型开发所需的建筑信息来自医院的建筑和机械计划。还进行了两次现场调查,以确定电气设备和天然气设备的运行特性。将开发模型估算的年度电力和天然气消耗与公用事业数据进行比较,以进行模型验证。使用已开发的模型评估了五种节能措施,即降低LPD,安装高效窗户,降低LPD和改变窗户方法的组合方法,为OR安装单独的冷却器以及LPD降低和冷却器分离的另一种组合。仿真结果表明,通过将LPD从2.5降低至0.86 W / ft2,每年可节省12%的能源,而使用高效窗口仅可节省1%。 LPD减少和窗口更改相结合可将年度能耗降低13%。分离OR制冷机后,建筑能耗降低了8%,通过减少LPD和分离制冷机的组合方法,建筑能耗降低了18%。

著录项

  • 作者

    Sardoueinasab, Zahra.;

  • 作者单位

    University of Louisiana at Lafayette.;

  • 授予单位 University of Louisiana at Lafayette.;
  • 学科 Energy.;Civil engineering.;Mechanical engineering.
  • 学位 M.S.
  • 年度 2017
  • 页码 72 p.
  • 总页数 72
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号