摘要

Atomic absorption spectrometry ( AAS) , inductively coupled plasma atomic emission spectrome-try (ICP-AES) and ion chromatography (IC) were used for determining the potassium, sodium, calcium and magnesium ions in precipitation .As compared to the detection limit , precision, accuracy and recovery rate , and the determination results of precipitation samples were analyzed by t test.The results showed that , the three methods could meet the requirement of quality control , there was no significant difference among the determina-tion results.Compared with the national standard method of AAS , ICP-AES method and IC method were more simple in operation and simultaneous determination of multiple elements were available .%采用原子吸收光谱法(AAS)、电感耦合等离子体发射光谱法(ICP-AES)和离子色谱法(IC)分别测定降水中的钾、钠、钙、镁,对检出限、精密度、准确度和加标回收率等指标作比对,并对降水样品的测定结果进行t检验。结果表明,3种方法均能满足质量控制的要求,测定结果之间无显著性差异;与国标方法AAS法相比,ICP-AES法和IC法操作更简单,并可实现多元素的同时分析。