首页> 中文期刊> 《分析仪器》 >ICP-AES法测定TB6钛合金中杂质元素

ICP-AES法测定TB6钛合金中杂质元素

         

摘要

A method of determination of Mo ,Cr ,Sn ,Zr ,Cu and B in TB6 titanium alloy by inductive-ly coupled plasma atomic emission spectrometry (ICP-AES ) was established. The sample was decomposed with hydrochloric ,hydrofucoric and nitric acid ,the interference from main co-existing elements were stud-ied to choose the analytical lines. The experiment of selection of analysis lines were :Mo 202.031 nm , Cr267.716 nm ,Sn 189.927 nm ,Zr 343.823 nm ,Cu 324.754 nm ,B 249.772 nm. The matrix effect was corrected by matrix matching .The determination results are in good agreement with standard reference materials .The recovery rate is from 90 to 106% ,the RSD is less than 2%.%本文介绍了用电感耦合等离子体发射光谱法(ICP-AES)法测定 TB6钛合金中杂质元素Mo、Cr、Sn、Zr、Cu和B的方法。样品采用盐酸、氢氟酸和硝酸溶解,考察了钛合金基体和共存元素对待测元素的影响,确定了各待测元素谱线分别为:Mo 202.031 nm、Cr 267.716 nm、Sn 189.927 nm、Zr 343.823 nm、Cu 324.754 nm、Si 251.611 nm、B 249.772 nm。选定的待测元素分析线不受合金基体和共存元素的谱线干扰。通过基体匹配消除基体的影响。选择了仪器工作参数,进行了标准物质对照试验,试验结果与标准值相符。进行了加入回收试验,回收率在90%~106%之间,相对标准偏差小于2%。

著录项

  • 来源
    《分析仪器》 |2014年第1期|43-46|共4页
  • 作者

    庞晓辉; 高颂; 王桂军;

  • 作者单位

    中航工业北京航空材料研究院;

    北京100095;

    航空材料检测与评价北京市重点实验室;

    北京100095;

    中航 试金石 检测科技有限公司;

    北京100095;

    中航工业北京航空材料研究院;

    北京100095;

    中航工业北京航空材料研究院;

    北京100095;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    TB6钛合金; 杂质元素; ICP-AES;