首页> 中文期刊> 《化工学报》 >螺旋板换热器轴向错流通道湿法捕尘拟均相模型

螺旋板换热器轴向错流通道湿法捕尘拟均相模型

         

摘要

提出了螺旋板换热器轴向错流通道冷却冷凝湿法除尘的方法,指出了 PM2.5在尾气对流传热传质边界层内热泳和伴随水蒸气冷凝的扩散泳运动特征和冷凝液膜吸收除尘机理并建立了拟均相模型,获得了 PM2.5浓度衰减函数和以冷凝通量nw为参数的捕尘效率模型。通过“三传”类比获得了从尾气流速求取模型参数的方法,并通过恒壁温条件下冷却冷凝实验数据验证了模型参数计算方法的正确性,结果表明水蒸气组分扩散体积通量即 PM2.5扩散泳速度Vw是控制性参数,其值在20~40 mm·s-1范围。%A wet process of PM2.5 removal from industrial waste gases was proposed, with cooling and condensation in the axial channel of a spiral plate exchanger. The characteristics of thermo-phoresis and diffusion-phoresis of PM2.5 with vapor component in the boundary layer of heat and mass transfer were pointed out. A pseudo-homogeneous model was built based on the mechanism on dust removal by condensate film absorption. Subsequently, the attenuation function of PM2.5 concentration was deduced. The dust removal efficiency equation, with the condensate flux nw and the waste gas inlet velocity u0 as the variables, was obtained. Parameters in the model were derived by means of analogies of momentum, heat and mass transfer, and verified with the experimental data of cooling and condensation under constant wall temperatures. It is shown that the key factor is the vapor diffusion volume flux (or called PM2.5 diffusion-phoresis velocity) Vw with the magnitude of 20-40 mm·s-1.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信