首页> 中文期刊> 《当代医学科学(英文)》 >Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake

Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake

         

摘要

The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction.

著录项

  • 来源
    《当代医学科学(英文)》 |2020年第1期|P.178-183|共6页
  • 作者单位

    Department of Radiology Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

    Department of Radiology Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

    Department of Radiology Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

    Department of Radiology Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

    Department of Radiology Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

    Department of Health Records Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

    Department of Radiology Tongji Hospital Tongji Medical College Huazhong University of Science and Technology Wuhan 430030 China;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 计算技术、计算机技术;
  • 关键词

    tube voltage; contrast agent; coronary CT angiography; radiation dose; iodine intake;

    机译:管电压;造影剂;冠状CT血管造影;放射剂量;碘摄入;