首页> 中文期刊> 《国际设备工程与管理:英文版》 >Research on Loose Reason of Fixing Bolt of Step Connector based on Finite Element Analysis

Research on Loose Reason of Fixing Bolt of Step Connector based on Finite Element Analysis

         

摘要

There are two connection modes between escalator step and step drive chain of outer roller,connector type A and type B.Connector type B after a period of running was found that the fixing bolt on the connector has loosened,which causes safety risks.In order to eliminate this security issue,the finite element modeling is proposed to analyze the relationship between the force generated by the connector type A or type B during the step band running and the assembly clearance or the assembly mode.So as to find out the root cause of fixing bolt loosening phenomenon,by redesigning the assembly clearance between the connector shaft and the chain hole,the fixing bolt of the connector is prevented from loosening during the step band running,ensuring the safe operation of escalators to avoid injury accidents.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有