首页> 中文期刊> 《质谱学报》 >高分辨电感耦合等离子体质谱法测量放射性废液中239Pu与240Pu

高分辨电感耦合等离子体质谱法测量放射性废液中239Pu与240Pu

         

摘要

239Pu和240Pu含量对分析放射性废液来源、选择后续处理工艺十分关键.本研究应用高分辨电感耦合等离子体质谱法 (HR-ICP-MS) 直接测定放射性废液中的239Pu、240Pu含量.由于238 U与1 H结合产生的铀氢复合离子会对239Pu、240Pu造成同质异位素干扰, 本研究通过测定铀氢复合离子产率进行质谱干扰修正, 将239Pu、240Pu系列浓度标准扣除铀氢复合离子干扰后, 分别绘制239Pu、240Pu质量浓度-计数率标准曲线.测量放射性废液样品时, 先利用铀氢复合离子产率修正239Pu和240Pu的同质异位素干扰, 再将样品计数率值代入标准曲线方程, 计算得到放射性废液样品中239Pu和240Pu的质量浓度, 最后计算239Pu和240Pu的活度.将质谱法与液闪法测量结果进行比对, 结果表明, 两者所测结果偏差小于4%, 方法相对扩展不确定度为4.6% (k=2) .该方法制样简单, 适用于辐射水平高、铀基体含量大的放射性废液中239Pu和240Pu的快速测量.%The accurate determination of concentration of 239 Pu and 240 Pu is very important not only for estimating the source of radioactive liquid waste, but also for selecting the subsequent disposal strategy.In this paper, a direct method using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) to measure the concentration of 239 Pu and 240 Pu in radioactive liquid waste was proposed.The main problem inthe determination of 239 Pu and 240 Pu by HR-ICP-MS is the isobaric interferences caused by uranium (~ (238) U1 H+and 238 U1 H2+) which always exists in the radioactive waste liquid with a higher concentration.This work provided a strategy to eliminate these isobaric interferences without separating the uranium from the radioactive liquid waste.Through the measurement of a series of uranium standard solutions with different concentrations by HR-ICP-MS, it was found that the yields of 238 U1 H+and 238 U1 H2+had positive correlation with the concentration of uranium.Besides, the ratios were constant:r (~ (238) U1 H+/238 U) =4.85×10-5, r (~ (238) U1 H2+/238 U) =2.99×10-6.Moreover, after using the yields of 238 U1 H+and 238 U1 H2+to deduct the isobaric interferences caused by uranium, the measurement results of the 0.1μg/L plutonium standard solution under different uranium matrix interference were roughly equal, indicating that the method to eliminate the isobaric interferences caused by uranium was reasonable and feasible.Furthermore, in order to get the mass concentration-counting rate standard curves for 239 Pu and 240 Pu, a series of the plutonium standard solution at different concentration was also measured.After deducting the isobaric interferences, the mass concentration of 239 Pu and 240 Pu in the samples of radioactive liquid waste could be calculated by the standard curve equation, and then the activity concentration of 239 Pu and 240 Pu in different samples were also calculated.In addition, the results were also compared with those obtained from the liquid scintillation counting method.The deviations between the results from HR-ICP-MS and the liquid scintillation method are less than 4%, and the relative expansion uncertainty is 4.6% (k=2) .The proposed method was proved as very effective to overcome the isobaric interferences caused by 238 U1 H+and 238 U1 H2+with minimal sample preparation (e.g., no need to separate the uranium) , which make it a fast, sensitive and accurate method to analyze 239 Pu and 240 Pu in radioactive waste liquid with abundant uranium existing.

著录项

  • 来源
    《质谱学报》 |2018年第5期|593-598|共6页
  • 作者单位

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

    中国核动力研究设计院第一研究所;

    四川省核设施退役及放射性废物治理工程实验室;

    四川 成都 610005;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 质谱分析;
  • 关键词

    高分辨电感耦合等离子体质谱 (HR-ICP-MS); 放射性废液; 铀; 钚; 同质异位素;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号