Based on the microorganism kinetic model, the formula for computing hydraulic retention time in a membrane bioreactor system (MBR) is derived. With considering HRT as an evaluation index a combinational approach was used to discuss factors which have an effect on MBR. As a result, the influencing factors were listed in order from strength to weakness as: maximum specific removal rate K , saturation constant K s, maintenance coefficient m , maximum specific growth rate μ m and observed yield coefficient Y obs . Moreover, the formula was simplified, whose parameters were experimentally determined in petrochemical wastewater treatment. The simplified formula is θ=1.1(1/β-1)(K s +S)/KX 0, for petrochemical wastewater treatment K and K s equaled 0 185 and 154.2, respectively.