In light of the possibility of reignition when unsealing the closed fire zones, the occurrence of reignition was simulated by a home-made experimental device, hydrogen variety rule from combustion to unsealing was analyzed, the three-stage generation model of hydrogen during reignition in fire zone was put forward and the probability that hydrogen was taken as an indicator gas was discussed. The results show that: when fire zone is ready to unseal, which is filled with hydrogen at a high concentration, it is more prone to reignite.