首页> 中文期刊> 《噪声与振动控制》 >室内声环境标准限值合理性实验研究

室内声环境标准限值合理性实验研究

         

摘要

Present room emission limits of fixed equipment noise transmitted by structures are considered incapable to predict subjective perception rationally. In this study, white noise of 31.5 ~ 500 Hz octave bands through filtration is adjusted to the sound pressure levels (SPL) of standard limits to form the original sound samples. New sound samples are produced by moderately adjusting the SPL of these 5 octave bands. Subjective annoyance tests are carried out using paired comparison method. The results indicate that, under the condition of equal A-weighted SPL or equal loudness levels, the new sound samples, whose SPL of 31.5 Hz and 63 Hz octave bands are reduced and SPL of 125 Hz and 250 Hz and 500 Hz octave bands are increased, are less annoying than the original sound samples. There is a significant correlation between SPL of 31.5 Hz octave band and the subjective annoyance rating (p < 0.01), and Pearson' s correlation coefficient is 0.925 ~ 0.951.%我国现行的结构传播固定设备室内噪声排放限值不尽合理.通过将白噪声滤波获得31.5~500Hz各倍频程带宽样本,调整其声压级至标准限值后合成原始声样本,并适当调整各倍频程频带声压级,合成新的声样本,采用成对比较法,对比研究各声样本的主观烦恼.结果表明,在A声级或响度级相同情况下,降低31.5 Hz与63 Hz倍频程频带声压级,并提高125 Hz、250 Hz及500Hz倍频程频带声压级,声样本主观烦恼均小于原始声样本;在各倍频程中,31.5 Hz倍频程频带声压级与声样本主观烦恼度最为相关,且呈显著正相关(p<0.01),Pearson相关系数为0.925~0.951.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号