首页> 中文期刊> 《核电子学与探测技术》 >放射性废液取样手套箱厚度最优化的蒙特卡罗计算

放射性废液取样手套箱厚度最优化的蒙特卡罗计算

         

摘要

Radioactive waste sampling glove box can reduce the damaging effects of radiation distilled residue of staff,in order to meet the requirements of radiation protection and optimization, to determine the thickness of the shield glove box,making the integrated irradiation due to personal total effective dose not to exceed the dose limit at the same value and achieve optimal levels is very important. In this paper, MCNP procedures for stainless steel glove box shielding calculations are applied to the cost-benefit analysis of radioactive waste derived optimal sampling glove box shielding layer thickness.%放射性废液取样手套箱可降低蒸残液对工作人员的辐射危害作用,为使综合照射所致个人总有效剂量不超过相应剂量限值的同时达到最优化水平,确定手套箱屏蔽厚度.本文采用MCNP程序对不锈钢手套箱厚度进行屏蔽计算,应用代价利益分析法,得出放射性废液取样手套箱最优化屏蔽层厚度.