首页> 外文期刊>核技术:英文版 >Image quality of the proton imaging from computer-simulated data
【24h】

Image quality of the proton imaging from computer-simulated data

机译:来自计算机模拟数据的质子成像的图像质量

获取原文
获取原文并翻译 | 示例
       

摘要

In this paper,the proton image quality of three designed phantoms is studied by the Monte Carlo simulation tool FLUKA,and is compared with that of the photon,and electron imaging.The passages of parallel beams were simulated by the phantoms for protons,electrons and X-rays,and the fluence and energy spectra of exiting particles are recorded.The proton energy loss imaging has a high quality under low transmission proton fluence,and its quality is superior to that of electron and photon fluence.The results demonstrate that proton energy loss imaging is especially suitable for the samples of hundreds of nano-thicknesses.