首页> 中文期刊> 《眼视光学杂志(英文版)》 >Safety and efficacy outcomes of the XEN45 Gel Stent use for refractory glaucoma:a surgery series from surgeon trainees at a tertiary teaching hospital

Safety and efficacy outcomes of the XEN45 Gel Stent use for refractory glaucoma:a surgery series from surgeon trainees at a tertiary teaching hospital

         

摘要

Background:To study the effect of an ab interno gelatin stent (XEN45 Gel Stent,Allergan Inc.,Irvine,California,USA) on intraocular pressure (lOP) as placed by glaucoma fellowship trainees in eyes with refractory glaucoma.Methods:A prospective noncomparative study at a tertiary training center on 28 unique eyes undergoing ab interno gelatin stent implantation by glaucoma fellowship trainees.Data was collected at baseline and postoperatively at day 1,week 1,and months 1,3,5,and 12.Primary outcome was mean lOP change.Secondary outcomes included change in number of glaucoma medication classes and visual acuity.Safety outcomes included needling rates.Surgical success was defined as achieving ≥ 20% reduction in lOP with the same or fewer classes of antiglaucoma medications from baseline without the need for secondary surgical intervention and/or stent removal.Results:At baseline,28.6% (8/28) of the subjects had prior failed incisional glaucoma surgery in a study population that was 54% African-American,with 78% with severe glaucoma (average mean deviation of-14.58 dB).Thirteen subjects terminated their clinic visits before their 12-month postoperative visit,leaving 15 subjects for end point analysis.Average lOP went from 21.6 mmHg (range 12.0-31.0,SD 6.6) at baseline to 12.5 mmHg (range 7.0-19.0,SD 3.6),a 42.1% reduction (P < 0.007).All subjects decreased the number of medication classes they were taking with an average reduction of 3.8 (range 2-5,SD 0.9) to 1.3 (range 0-3,SD 1.0) classes,or a 65.8% decrease (P< 0.006).Crude surgical success was 80.0% for the 15 subjects that followed up at 12 months.The Kaplan-Meier cumulative probability of success for all 28 subjects at 12 months was 70.4% (95% CI:44.7-85.8%).Regardless of the length of follow-up,21.4%(6/28) met failure criteria:3 subjects failed because they required secondary surgical intervention,and the other 3 did not have adequate lOP reduction.Initial bleb needling rate was 28.6% (8/28) and repeat was 17.9% (5/28).Conclusions:Compared to the reported literature with experienced ocular surgeons,ab interno gel stent placements by glaucoma fellowship trainees have similar mean lOP,topical medication reduction,surgical success,and needling rates at 12-month follow-up.

著录项

  • 来源
    《眼视光学杂志(英文版)》 |2021年第4期|12-22|共11页
  • 作者

  • 作者单位

    华盛顿大学;

  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号