首页> 中文期刊> 《山西建筑》 >梁端柔性对装配式框架结构的内力影响

梁端柔性对装配式框架结构的内力影响

         

摘要

Through using finite element method, the effect of ductile connections on internal force of frame structure is discussed. The results show that: under vertical loads, compared to the rigid connection, the girder end bending moment and column base moment will decrease, while the mid-span bending moment increases, under horizontal loads, compared to the rigid connection, the girder end bending moment decreases and column base moment increase significantly, while the mid-span bending moment does not change, under vertical loads and under horizontal loads at the same time, the internal difference between rigid and ductile connection is also obvious.%通过采用有限单元法进行分析,研究了柔性连接对框架结构内力的影响。研究表明,在竖向荷载作用下,相比较于刚性连接,梁端弯矩和柱脚弯矩均减小,而梁跨中弯矩变大。在水平荷载作用下,相比较于刚性连接,梁端弯矩减小,底层柱脚弯矩明显增大,此时梁跨中的弯矩几乎没有变化。当水平荷载和竖向荷载共同作用时,刚性连接与柔性连接之间的内力差别也是显著的。