摘要

为减少建筑热水能耗,该文研究了一种新型太阳能光伏环路热管热水系统.该系统将太阳能光伏光热利用与环路热管有机结合,并以电加热为辅助热源制备生活热水.搭建了室外测试平台,对该系统进行了典型工况及全天性能的测试研究,分析了循环工质充注量对系统性能的影响.结果显示,系统在环路热管运行模式下,夏季工况的光热效率和综合能源效率最高,日平均值分别为62.1%和68.1%;冬季工况的光电效率和综合效率最高,日平均值分别为13.7%和10.9%.整套系统的综合能源效率和综合效率略高于环路热管模式.30%充注量的工况更有利于系统光热效率和光电光热综合能源效率的提高,40%充注量的工况则有利于系统光电光热综合效率的提高.该研究表明太阳能光伏环路热管热水系统在寒冷地区运行性能良好,为系统工质充注量的选择提供了参考依据.%The aim of this paper was to present a dedicated experimental investigation of the thermal and electrical performance of a solar photovoltaic/loop-heat-pipe water heating system. The studied system was the combination of the loop heat pipe and the solar photovoltaic/thermal technology, which was assisted by the electric water heater to product hot water for residential buildings in cold zone. The proposed system could work in 2 operational modes, and the operational modes were mainly determined by the variation of solar radiation. When solar radiation was high, the system operated in the photovoltaic/loop-heat-pipe mode; when solar radiation was low or it was a rainy day, the electric water heater was turned on to heat water to match the preset value. The experimental platform for the solar photovoltaic/loop-heat-pipe water heating system was built and a series of experiments under real weather conditions were conducted. Based on test results, energy and exergy performance of the studied system under typical working condition was analyzed. And the typical working conditions include the transitional season condition, the summer condition and the winter condition. Besides, energy and exergy performance of the system on the specific 2 days was discussed and compared. What was more, the impact of the refrigerant charge quantity on the operating performance was analyzed. Therefore, main content of this paper was composed of energy and exergy performance analyses under typical working conditions and selected full days. The experimental results in the photovoltaic/loop-heat-pipe mode were analyzed in terms of the solar thermal efficiency, the photovoltaic efficiency, the overall energy efficiency and the overall exergy efficiency. For the solar thermal efficiency and overall energy efficiency, the experimental results were the highest in summer, and the daily average values were 62.1% and 68.1% respectively. For the photovoltaic efficiency and overall exergy efficiency, the experimental results were the highest in winter, and the daily average values of them were 13.7% and 10.9% respectively. The whole system performance considered the performance of 2 operational modes, and therefore the overall energy and exergy efficiency of the whole system were a litter higher than those of the mode of photovoltaic/loop-heat-pipe. In this paper, the experimental results of April 20thand December 9thwere chosen to analyze full-day performance of this system, and the solar thermal efficiency and overall energy efficiency were higher on April 20th, while the photovoltaic efficiency and overall exergy efficiency of full-day performance were higher on December 9th. This paper also discussed the system performance with different refrigerant charge quantities in similar ambient environment. And the results showed that 30% refrigerant charge quantity was conducive to the improvement of solar thermal efficiency and overall energy efficiency of this system and 40% refrigerant charge quantity was conducive to the improvement of electrical efficiency and overall exergy efficiency of this system.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号