首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System
【2h】

Considerations on Circuit Design and Data Acquisition of a Portable Surface Plasmon Resonance Biosensing System

机译:便携式表面等离子体共振生物传感系统的电路设计和数据采集的考虑

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to develop a circuit for an inexpensive portable biosensing system based on surface plasmon resonance spectroscopy. This portable biosensing system designed for field use is characterized by a special structure which consists of a microfluidic cell incorporating a right angle prism functionalized with a biomolecular identification membrane, a laser line generator and a data acquisition circuit board. The data structure, data memory capacity and a line charge-coupled device (CCD) array with a driving circuit for collecting the photoelectric signals are intensively focused on and the high performance analog-to-digital (A/D) converter is comprehensively evaluated. The interface circuit and the photoelectric signal amplifier circuit are first studied to obtain the weak signals from the line CCD array in this experiment. Quantitative measurements for validating the sensitivity of the biosensing system were implemented using ethanol solutions of various concentrations indicated by volume fractions of 5%, 8%, 15%, 20%, 25%, and 30%, respectively, without a biomembrane immobilized on the surface of the SPR sensor. The experiments demonstrated that it is possible to detect a change in the refractive index of an ethanol solution with a sensitivity of 4.99838 × 105 ΔRU/RI in terms of the changes in delta response unit with refractive index using this SPR biosensing system, whereby the theoretical limit of detection of 3.3537 × 10−5 refractive index unit (RIU) and a high linearity at the correlation coefficient of 0.98065. The results obtained from a series of tests confirmed the practicality of this cost-effective portable SPR biosensing system.
机译:这项研究的目的是开发一种基于表面等离振子共振光谱学的廉价便携式生物传感系统的电路。这种专为现场使用而设计的便携式生物传感系统的特征在于特殊的结构,该结构由微流控单元组成,该微流控单元包括用生物分子识别膜功能化的直角棱镜,激光线发生器和数据采集电路板。数据结构,数据存储容量和带有用于收集光电信号的驱动电路的线电荷耦合器件(CCD)阵列得到了广泛的关注,并对高性能的模数(A / D)转换器进行了全面评估。在本实验中,首先研究了接口电路和光电信号放大电路,以从线CCD阵列获得微弱信号。使用浓度分别为5%,8%,15%,20%,25%和30%的体积分数表示的各种浓度的乙醇溶液进行定量验证生物传感系统灵敏度的定量测量,而没有固定生物膜。 SPR传感器的表面。实验表明,利用Δ响应单元随折射率的变化,可以检测出乙醇溶液的折射率变化,灵敏度为4.99838×10 5 ΔRU/ RI。此SPR生物传感系统的理论检测极限为3.3537×10 -5 折射率单位(RIU),相关系数为0.98065时具有很高的线性。通过一系列测试获得的结果证实了这种经济高效的便携式SPR生物传感系统的实用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号