The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor’s own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field.
机译:纤维蛋白原水平的测定是医学上最重要的凝血指标之一。它在诊断和治疗决策中起着至关重要的作用,通常与时效性疾病相关。常用的测量方法是克劳斯纤维蛋白原测定法(CFA),其中血浆通过凝血酶试剂激活,并通过机械/比浊仪进行。由于基于耗散(QCM-D)的石英晶体微天平传感器的占地面积小,易于操作并且可以独立于样品运输时间,实验室位置,可用性和开放时间进行测量,因此它们为补充实验室CFA测量提供了绝佳机会。因此,工作的目的是(1)将CFA转换为QCM-D方法; (2)开发一种简单,省时且具有成本效益的程序,(3)将结果与参考进行比较。对不同的传感器涂层(供体自身的等离子体;金表面)和不同的QCM-D参数(频率信号偏移;其计算出的转折点;耗散信号偏移)进行了采样。结果表明在生理性纤维蛋白原范围内适用于基于QCM-D的CFA。在不到1分钟的时间内获得了结果,并且与标准参考值(Merlin凝血计)非常吻合。该结果为进一步研究提供了良好的基础,并为QCM-D在医学领域的临床和非临床常规应用中的可能应用铺平了道路。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号