首页> 美国卫生研究院文献>Biomedical Optics Express >Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography
【2h】

Spectrometer calibration for spectroscopic Fourier domain optical coherence tomography

机译:光谱傅里叶域光学相干层析成像仪的光谱仪校准

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We propose a simple and robust procedure for Fourier domain optical coherence tomography (FdOCT) that allows to linearize the detected FdOCT spectra to wavenumber domain and, at the same time, to determine the wavelength of light for each point of detected spectrum. We show that in this approach it is possible to use any measurable physical quantity that has linear dependency on wavenumber and can be extracted from spectral fringes. The actual values of the measured quantity have no importance for the algorithm and do not need to be known at any stage of the procedure. As example we calibrate a spectral OCT spectrometer using Doppler frequency. The technique of spectral calibration can be in principle adapted to of all kind of Fourier domain OCT devices.
机译:我们提出了一种用于傅里叶域光学相干断层扫描(FdOCT)的简单而健壮的过程,该过程允许将检测到的FdOCT光谱线性化为波数域,并同时确定检测到光谱的每个点的光波长。我们表明,在这种方法中,可以使用对波数具有线性依赖性并且可以从频谱条纹提取的任何可测量物理量。测量量的实际值对算法不重要,不需要在过程的任何阶段都知道。例如,我们使用多普勒频率校准光谱OCT光谱仪。光谱校准技术原则上可以适用于所有种类的傅里叶域OCT设备。