X-ray Emission Spectroscopy as an In Situ Diagnostic Tool for X-ray Crystallography of Metalloproteins Using an X-ray Free Electron Laser

机译:X射线发射光谱作为使用X射线自由电子激光对金属蛋白进行X射线晶体学分析的原位诊断工具

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Serial femtosecond crystallography (SFX) using the ultra-short X-ray pulses from a X-ray free-electron laser (XFEL) provides a new way of collecting structural data at room temperature that allows for following the reaction in real time after initiation. XFEL experiments are conducted in a shot-by-shot mode as the sample is destroyed and replenished after each X-ray pulse – monitoring and controlling the data quality by using in situ diagnostic tools is thus critical. To study metalloenzymes, we developed the use of simultaneous collection of X-ray diffraction of crystals along with X-ray emission spectroscopy (XES) data that is used as a diagnostic tool for crystallography, by monitoring the chemical state of the metal catalytic center. We have optimized data analysis methods and sample delivery techniques for fast and active feedback to ensure the quality of each batch of samples and the turnover of the catalytic reaction caused by reaction triggering methods. Here, we describe this active in situ feedback system using Photosystem II as an example that catalyzes the oxidation of H2O to O2 at the Mn4CaO5 active site. We used the first moments of the Mn Kβ1,3 emission spectra, highly sensitive to the oxidation state of Mn, as the primary diagnostics. This approach is applicable to different metalloproteins to determine the integrity of samples and follow changes in the chemical states of the reaction that can be initiated by light or activated by substrates, and offers a metric for determining the diffraction images that are used for the final datasets.
机译:使用来自X射线自由电子激光器(XFEL)的超短X射线脉冲的连续飞秒晶体学(SFX)提供了一种在室温下收集结构数据的新方法,该方法可在引发后实时跟踪反应。 XFEL实验是逐次进行的,因为每个X射线脉冲后都会破坏并补充样品,因此使用现场诊断工具监控和控制数据质量至关重要。为了研究金属酶,我们通过监测金属催化中心的化学状态,开发了同时收集晶体的X射线衍射和X射线发射光谱(XES)数据(用作晶体学诊断工具)的方法。我们优化了数据分析方法和样品传递技术,以实现快速,主动的反馈,以确保每批样品的质量以及由反应触发方法引起的催化反应的周转率。在这里,我们以Photosystem II为例,描述此主动原位反馈系统,该系统在Mn4CaO5活性位点催化H2O氧化为O2。我们使用对Mn的氧化态高度敏感的MnKβ1,3发射光谱的第一刻作为主要诊断方法。该方法适用于不同的金属蛋白,以确定样品的完整性并跟踪反应的化学状态变化(可以通过光引发或通过底物激活),并提供一种度量标准,用于确定用于最终数据集的衍射图像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号