首页> 美国卫生研究院文献>other >Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography
【2h】

Catheter radiofrequency ablation for arrhythmias under the guidance of the Carto 3 three-dimensional mapping system in an operating room without digital subtraction angiography

机译:在无数字减影血管造影的手术室中在Carto 3三维绘图系统的指导下对心律失常进行导管射频消融

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Several studies have reported the efficacy of a zero-fluoroscopy approach for catheter radiofrequency ablation of arrhythmias in a digital subtraction angiography (DSA) room. However, no reports are available on the ablation of arrhythmias in the absence of DSA in the operating room. To investigate the efficacy and safety of catheter radiofrequency ablation for arrhythmias under the guidance of a Carto 3 three-dimensional (3D) mapping system in an operating room without DSA. Patients were enrolled according to the type of arrhythmia. The Carto 3 mapping system was used to reconstruct heart models and guide the electrophysiologic examination, mapping, and ablation. The total procedure, reconstruction, electrophysiologic examination, and mapping times were recorded. Furthermore, immediate success rates and complications were also recorded. A total of 20 patients were enrolled, including 12 males. The average age was 51.3 ± 17.2 (19–76) years. Nine cases of atrioventricular nodal re-entrant tachycardia, 7 cases of frequent ventricular premature contractions, 3 cases of Wolff–Parkinson–White syndrome, and 1 case of typical atrial flutter were included. All arrhythmias were successfully ablated. The procedure time was 127.0 ± 21.0 (99–177) minutes, the reconstruction time was 6.5 ± 2.9 (3–14) minutes, the electrophysiologic study time was 10.4 ± 3.4 (6–20) minutes, and the mapping time was 11.7 ± 8.3 (3–36) minutes. No complications occurred. Radiofrequency ablation of arrhythmias without DSA is effective and feasible under the guidance of the Carto 3 mapping system. However, the electrophysiology physician must have sufficient experience, and related emergency measures must be present to ensure safety.
机译:数项研究报告了零透视法在数字减影血管造影(DSA)室中对心律失常的导管射频消融的功效。但是,在没有DSA的手术室中,尚无消融心律失常的报道。在无DSA的手术室中,在Carto 3三维(3D)测绘系统的指导下研究导管射频消融治疗心律不齐的疗效和安全性。根据心律失常的类型招募患者。 Carto 3绘图系统用于重建心脏模型并指导电生理检查,绘图和消融。记录整个过程,重建,电生理检查和作图时间。此外,还记录了即时成功率和并发症。总共招募了20名患者,其中包括12名男性。平均年龄为51.3±17.2(19-76)岁。其中包括9例房室结折返性心动过速,7例频繁的室性早搏,3例Wolff–Parkinson–White综合征和1例典型的房扑。所有心律不齐均已成功消融。手术时间为127.0±21.0(99-177)分钟,重建时间为6.5±2.9(3-14)分钟,电生理研究时间为10.4±3.4(6-20)分钟,作图时间为11.7±±。 8.3(3–36)分钟。没有并发症发生。在DSC成像系统的指导下,不进行DSA的射频消融心律失常是有效和可行的。但是,电生理医师必须具有足够的经验,并且必须采取相关的紧急措施以确保安全。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号