This paper presents a newly-designed and realized Invasive Blood Pressure (IBP) device for the simulation on patient’s monitors. This device shows improvements and presents extended features with respect to a first prototype presented by the authors and similar systems available in the state-of-the-art. A peculiarity of the presented device is that all implemented features can be customized from the developer and from the point of view of the end user. The realized device has been tested, and its performances in terms of accuracy and of the back-loop measurement of the output for the blood pressure regulation utilization have been described. In particular, an accuracy of ±1 mmHg at 25 °C, on a range from −30 to 300 mmHg, was evaluated under different test conditions. The designed device is an ideal tool for testing IBP modules, for zero setting, and for calibrations. The implemented extended features, like the generation of custom waveforms and the Universal Serial Bus (USB) connectivity, allow use of this device in a wide range of applications, from research to equipment maintenance in clinical environments to educational purposes. Moreover, the presented device represents an innovation, both in terms of technology and methodologies: It allows quick and efficient tests to verify the proper functioning of IBP module of patients’ monitors. With this innovative device, tests can be performed directly in the field and faster procedures can be implemented by the clinical maintenance personnel. This device is an open source project and all materials, hardware, and software are fully available for interested developers or researchers.
机译:本文介绍了一种新设计并实现的有创血压(IBP)设备,用于在患者监护仪上进行模拟。该设备相对于作者提出的第一个原型和最先进的类似系统,显示出改进并提供了扩展功能。所提出的设备的特点是,可以从开发人员和最终用户的角度来定制所有实现的功能。已经对实现的装置进行了测试,并且已经描述了其在准确性和针对血压调节利用的输出的回路测量方面的性能。尤其是,在不同的测试条件下,在25至30°C至300 mmHg的范围内,其精度为±1 mmHg。设计的设备是测试IBP模块,进行零位设置和校准的理想工具。已实现的扩展功能(如生成自定义波形和通用串行总线(USB)连接)使该设备可在从研究到临床环境中的设备维护再到教学目的的广泛应用中使用。此外,所展示的设备在技术和方法论上都代表着一项创新:它允许进行快速有效的测试,以验证患者监护仪的IBP模块是否正常运行。使用这种创新的设备,可以直接在现场进行测试,并且临床维护人员可以执行更快的程序。该设备是一个开源项目,所有材料,硬件和软件均可供感兴趣的开发人员或研究人员使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号